In Concrete Heating Cable 17W/Lm

In Concrete Heating Cable 17W/Lm

NZ$89.56
Product code: ICH170300

Availability: In stock

Quick Overview:

In Concrete Heating Cable 17W/Lm is the smaller linear wattage that allows the heating cable to be spaced closer and so can be laid 20-30mm below a coloured concrete overlay.

* Required Fields

NZ$89.56
 

Details

17 Watts/Lm In Concrete Heating Cable Diagram:

 

 1 = Multi Stranded Heating Conductor (0.25mm-0.68)

 2 = Conductor Insulation 0.5mm RTI XPLE (natural)

 3 = Return Conductor AWG 20/7/28 TPC (0.5mm2): AWG 19/10/28 TPC (0.75mm2)

 4 = Return Conductor Insulation 0.5mm RTI XPLE 9natural)

 5 = Earth Conductor 1.0mm TPC (0.9mm2)

 6 = Aluminised Mylar Tape 15mm width & 65 Micron Thickness

 7 = Outer Insulation 1.5mm RTI High Temp PVC

 

 Working temperature 105 Degrees C

 Working voltage 230V AC, 50Hz

 Cable Dia 6.0mm

 Cold Tail 3.5m

 

Loading Design Specifications:

1. We recommend the below design loadings and using the heating cable chart above. 

Living Areas: 130-180W/m2

Bedrooms/Bathrooms/Hallways/Wooden Floors: 80-100W/m2

Freezers & Pipes: 20-40W/m2 (You may require electrical engineer heat load design)

2. The Maximum load = 17W/Lm

3. The cable operating temperature should not exceed 105 Degrees C

4. The Cable must be kept clear of any thermal insulation and upper floor surfaces with a minimum clearance of 25mm

 

See Thermostat Control Options

 

Watts m2LengthOhm/mAmps
300217.659.991.30
450326.474.441.95
600535.292.502.61
750644.121.603.26
900752.941.113.91
1050861.760.824.56
1200970.590.625.22
13501079.410.495.87
15001288.240.406.25
180014105.880.287.82
210016123.530.209.13
240018141.180.1610.43
300023176.470.1013.04
360028211.760.0715.65