In-concrete Heating Cable
Product Code: ICH
Details:
- Recommended for areas up to 50 m²
- Available in a range of wattages, from 450W to 3600W
- Maximum working temperature: 105C
- Keep cable clear of thermal insulation and upper floor surfaces with a minimum clearance of 25mm
- Working voltage: 230V AC 50Hz
- Cable diameter: 6.0mm
- Cold tail: 3.5m
- Recommended design loadings:
- Living Areas: 130W/m²
- Bedrooms, bathrooms, hallways, and wooden floors: 130-150W/m²
- Maximum load: 30W/Lm
Tredaire King Carpet Underlay greatly increases floor heating performance.
Required thermostat sold separately. View thermostat range.
If you don’t require a thermostat please contact us.
Availability: In stock
Product Downloads
Technical Specifications
Watts | Lm Lenght | Element Res | Core Res | Amps |
450 | 15 | 7.84 | 7.84 | 1.97 |
750 | 25 | 2.82 | 2.82 | 3.26 |
900 | 30 | 58.78 | 1.96 | 3.91 |
1200 | 40 | 44.08 | 1.10 | 5.21 |
1500 | 50 | 35.27 | 0.71 | 6.52 |
2100 | 70 | 25.19 | 0.36 | 9.13 |
2400 | 80 | 22.04 | 0.28 | 10.43 |
3000 | 100 | 17.63 | 0.18 | 13.04 |
3600 | 120 | 14.69 | 0.12 | 15.65 |